Latest HPE0-J68 Study Guides 2024 - With Test Engine PDF
Get New HPE0-J68 Practice Test Questions Answers
NEW QUESTION # 149
During a proof-of-concept you need to implement an inter-switch-link (ISL)between two HPE SN6000B switches. Which port mode must be set enable communication between the switches?
- A. N_PORT
- B. F_PORT
- C. FL_PORT (WRONG)
- D. E_PORT (Correct)
Answer: D
Explanation:
When implementing an Inter-Switch Link (ISL) between two HPE SN6000B switches, the correct port mode that must be set to enable communication between the switches is E_PORT. E_PORT stands for Expansion Port and is used to connect switches in a fabric. It facilitates the creation of an ISL that allows traffic to be routed between the switches in the fabric, enabling the switches to share the connected devices' routing tables and maintain a unified fabric.
NEW QUESTION # 150
In an ISCSI based storage system Proof-Of-Concept project ,the customer is not satisfied with the performance of their video streaming application .What would you recommended to the customer to optimize the excisting environment?
- A. Enable hardware ISCSI initiator
- B. Increase the switch buffer to buffer credits
- C. Enable jumbo frames on required components
- D. Consolidate the heterogeneous switches in the network
Answer: C
NEW QUESTION # 151
You are configuring a new HPE 3PAR solution and need to create a new disk group with a defined RAID level.
Click the appropriate option where the RAID can be selected.
Answer:
Explanation:
Explanation:
NEW QUESTION # 152
A customer need a new storage system for visual desktop infrastructure environment to reduce the time required to provision new desktop. Which HPE solution should you recommended to fulfill this customers requirements?
- A. SmartClone on HPE store virtual VSA(54)
- B. Storage pool on HPE store Easy
- C. Virtual Copy on HPE 3Par storeServ
- D. Snapclones on HPE MSA 2040
Answer: A
NEW QUESTION # 153
A customer is purchasing an HPE MSA 2050 for a branch office. They will use it for critical data services. The customer is concerned that 64 snapshots will not be adequate as they grow.
What can be added to the array to address the customer's concerns?
- A. All-inclusive Multi-system license
- B. Virtual Copy license
- C. Advanced Data Services Suite license
- D. Adaptive Optimization license
Answer: D
NEW QUESTION # 154
Refer to the exhibit.
You are designing a new Primera solution and demonstrating performance numbers to the customer. The customer reviews the configuration and requests a change to the configuration that will increase Random Write IOPS.
Which action will satisfy the customer request?
- A. Add more FC Ports
- B. Change to larger SSDs
- C. Upgrade the HPE Primera base model
- D. Add more disks of smaller capacity
Answer: B
NEW QUESTION # 155
Which software feature should an HPE 3PAR Storeserv 8000 customer use to optimize data protection and recovery, Including rapid online recovery for his VMware environment?(select two)
- A. HPE 3PAR File persona Software suite
- B. HPE StoreOnce recovery manager central for VMware
- C. HPE 3PAR Virtual Copy software
- D. HPE 3PAR Remote copy software
- E. HPE 3PAR Security software suite
Answer: B,C
NEW QUESTION # 156
Which 3PAR storeServ feature allow to host to continue I/O uninterrupted during a firmware update?
- A. Persistent Memory
- B. Persistent port (96)
- C. Peer persistence
Answer: B
Explanation:
D Persistent Cache
NEW QUESTION # 157
A customer with restricted budget has an existing HPE 3PAR storeserver 8200 using 10kfast class and near line drives because of the implementation of new application .the workload has shifted to be read intensive therefore ,they want to increase the read I/O performance What should they add to their environment ?
- A. A tier with 15k fast class drive and implement thin provisioned deduplicated virtual volumes
- B. Two 400 GB SSD drives and enable adaptive flash cache (page 173) eed to check
- C. A tier with 15k fast class 600 GB drive for new CPG, configure AO policy to advantage of new resources
- D. A tier of SSD and implement thin provisioned virtual volume
Answer: B
NEW QUESTION # 158
You have proposed a Primera array to a customer for primary storage. The customer currently has an older HPE 3PAR array and will continue to use it moving forward. The customer would like high availability configured.
Which RMC Peer Copy pre-requisites do you need to point out to the customer? (Choose two.)
- A. 4-port 1 Gb Ethernet Adapter (NIC) is required in each array
- B. Required license must be provided
- C. Target drive type must match source drive type
- D. RMC 6.2
- E. Check that the 3PAR OS version is supported
- F. 2-port 10 Gb Ethernet Adapter (NIC) is required in each array
Answer: A,B
NEW QUESTION # 159
A customer implemented the HPE StoreEver MSL6480 Tape Library.
Which HPE Software can the system administrator use to check the health of the library and monitor its utilization?
- A. InfoSight
- B. OneView
- C. StoreServe TapeAssure Advanced
- D. StoreEver Data Verification
Answer: C
Explanation:
For monitoring the health and utilization of the HPE StoreEver MSL6480 Tape Library, StoreServ TapeAssure Advanced is the recommended software. TapeAssure Advanced provides detailed insights into the operational status of tape libraries, including health checks, utilization metrics, and predictive analytics.
This tool is essential for ensuring the reliability and efficiency of tape storage environments.
References:
* HPE StoreEver Tape Libraries
* HPE TapeAssure Advanced
NEW QUESTION # 160
What HPE Alletra 9000 CLI command allows you to display teal-time statistics on exported volumes including roundtrip time of an 10 as seen by the system?
- A. srstatvlun
- B. statvlun
- C. statvv
- D. srstatvv
Answer: B
Explanation:
The statvlun command in the HPE Alletra 9000 CLI is used to display real-time statistics on exported volumes, including the roundtrip time (RTT) of an I/O as seen by the system. This command provides detailed insights into the performance of the volumes, helping administrators monitor and optimize the storage system's performance in real-time.
References:
* HPE Alletra 9000 CLI Commands
* HPE Storage Performance Monitoring
NEW QUESTION # 161
After a performance analysis, a customer plan to reorganize his adaptive Flash cache (AFC) configuration and want to raise it from 256 to 768GB. Which action is needed to take advantage of the new AFC configuration?
- A. Run tunesys after raising the AFC to take advantage of the additional space
- B. Remove flash cache for all VVS then run create Flash cache
- C. Increase current AFC configuration to reflect the additional space
- D. Remove the old AO configuration and recreate a new one
Answer: B
Explanation:
When adjusting the Adaptive Flash Cache (AFC) configuration in HPE 3PAR StoreServ, particularly when increasing the cache size, the correct procedure involves first removing the existing flash cache for all Virtual Volumes (VVs). After this step, you should recreate the flash cache to reflect the new increased capacity. This ensures that the system properly recognizes and utilizes the additional cache space, optimizing performance according to the new configuration.
References:
* HPE 3PAR StoreServ
* HPE Adaptive Flash Cache
NEW QUESTION # 162
Your customer would like to improve the security of their backups with HPE StoreOnce data-at-rest encryption. Which statement is true for this feature?
- A. It must be enabled during creation of the backup device
- B. It can be tested for free as a part of a demo license
- C. It is only supported by Catalyst Store
- D. It is a hardware assisted feature
Answer: A
Explanation:
This feature cannot be retroactively applied to existing backup devices; it must be configured at the time of setup to ensure that all data written to the storage device is encrypted. This hardware-assisted encryption feature is critical for enhancing the security of stored data, protecting it from unauthorized access in the event of physical theft or unauthorized access.
For further details, refer to:
* HPE StoreOnce Overview
NEW QUESTION # 163
Your customer has very low deduplication ratio of their Linux VMs farm which is hosted on a HPE Alletra
9000 Which fllesystem type could cause this?
- A. EXT3
- B. Btrfs
- C. XFS
- D. EXT4
Answer: C
Explanation:
A very low deduplication ratio in a Linux VM farm hosted on an HPE Alletra 9000 could be caused by the use of the XFS filesystem. XFS is known for its performance and scalability but is less effective in environments where deduplication is critical because of its data layout and file handling characteristics. This can lead to reduced deduplication efficiency compared to other filesystems like EXT4 or Btrfs.
For more information, refer to:
* HPE Alletra 9000 Documentation
NEW QUESTION # 164
A solution architect is sizing the required capacity for an HPE Alletra 9000. Customer requirements include:
* 100TB base volumes
* 168 snapshots a week
* 15% daily change rate
How much capacity is needed for snapshots after one week?
- A. 700TB
- B. 15TB
- C. 1680TB
- D. 105TB
Answer: D
Explanation:
To calculate the required capacity for snapshots after one week for an HPE Alletra 9000, we start by understanding the customer's requirements:
* Base volume size: 100TB
* Snapshots: 168 snapshots per week
* Daily change rate: 15%
The snapshot capacity requirement can be calculated by taking 15% of the base volume size per day, and multiplying it by the number of days (7 days in a week) and the number of snapshots per day.
Daily change: 15% of 100TB = 15TBTotal change over a week: 15TB * 7 days = 105TB Thus, the capacity needed for snapshots after one week is 105TB.
References:
* HPE Alletra 9000 Overview
* HPE Storage Snapshots
NEW QUESTION # 165
Which statement is correct when comparing functionalities of the AF and HF series in the Nimble storage portfolio? (Choose Two)
- A. Zero Copy Clones are a unique feature of All-Flash arrays within the Nimble Portfolio.
- B. HF series has a dedicated read cache and AF series does not have a dedicated reach cache.
- C. HF series supports storage snapshots and replication using Veeam Backup & Replication, HF and AF series support storage snapshots only
- D. >99.9999% availability is measured and guaranteed for AF and HF series arrays.
Answer: B,D
NEW QUESTION # 166
......
HPE0-J68 Dumps and Exam Test Engine: https://passleader.realexamfree.com/HPE0-J68-real-exam-dumps.html